Temporary Cone, Basket & Plate Strainer

Temporary strainers are specially designed for the filtration of debris and for the protection of equipment and instrumentation during commissioning and start-up periods. The strainers are usually installed between a set of flanges without any modification to the surrounding pipeline for an initial period after a new plant has been installed. Temporary strainers are suitable for working at high pressure differences. The flow goes from the inside out, and the collecting debris in the basket can easily be removed.

PELTECH can tailor-made temporary strainers according to customer specifications. Standard construction is perforated screen or a single ply heavy wire mesh. Wire mesh can be added inside / outside of the strainer for finer straining capabilities but must ensure that the direction of flow is against the wire mesh with the perforated metal as a back-up.

Applications

Steam, water, oil, other liquid or gas where protection of pumps, maters, valves, and other similar equipment in a pipeline is required. These strainers are installed between flanges without any modification to the surrounding pipeline.

Features

  • Open Area Range (OAR) of 100% to 300% available, 150% OAR as our standard.
  • Additional stiffeners or cross bracing can be installed on both TC and TB type strainer to prevent collapse.
  • Both TC and TB type strainer can be inverted to obtain higher percent of open area.
  • Custom engineered designs available.

Construction

The Peltech style TC, TB, & TP Strainers are available in stainless steel, monel, hastelloy, and other alloys upon request. Screens are available perforated, mesh or mesh lined to meet specific media requirement.

Standard Screens

The Peltech style TC, TB, & TP Strainers are normally supplied with perforation 3mm diameter holes on 5 mm centers / pitch.

Sizes

3/4″ (20 mm) up to 24” (600 mm) as standard. Larger sizes are available upon request.

When Ordering Specify

  • Pipe size
  • Style
  • Pressure rating
  • Perforation or mesh size
    (If mesh lined specify flow direction)
  • Material of construction

Screen Openings

If strainer is being used for protection rather than direct filtration, standard screens will suffice in most applications.

When choosing a perf or a mesh/perf combination, attention should be given to ensure overstraining does not occur. As a general rule, the specified level of filtration should be no smaller than half size of the particle to be removed. If too fine a filtration is specified, the pressure drop through the strainer will increase very rapidly.

Strainer SizeODIDD
150 – 300 lb (Sth.)600 lb900 lb1500 lbAll Flange RatingsAll Flange Ratings
Inmmmmmmmmmmmmmm
3/42054646767168
125647076761910
1-1/240839295953216
2501021081401404422
2-1/2651211271621625729
3801331461651717035
41001711912032069548
512519423824425111759
615021926328627913768
820027631835634918794
10250337397432432238119
12300406454495517279140
14350441483517575311156
16400511555572638356178
18450540603635702400200
20500597676695753445222
24600708784835899540270
Strainer SizeL
3.0 mm Perforations 5.0 mm centers, % Open area compared to cross section Sch 40 Pipe
ConesBaskets
100%150% (Sth)200%100%150% (Sth)200%
Inmmmmmmmmmmmmmm
3/420294357192938
125416484294357
1-1/2405686114385776
250761141525176102
2-1/265811271705686114
38010215921670108145
410013020027089136183
5125165257356114171232
6150207330432140216289
8200259406559178272381
10250330508686219356457
12300406610838267432559
14350432686914292457610
164005087871041356533711
184505848891194406610813
205006359911346432686889
24600762119416005338131067

Style TC: Cone Strainer
Style TB: Basket Strainer
Style TP: Plate Strainer

Our showcase

TB type
TB type
TC type
mesh conical strainer
internal support
serrated surface
Before dispatch