Pipeline strainers

LEAKPROOF Y-Strainer

A Y-strainer protects pumps, control valves, meters, steam traps and burners with a cylindrical screen in a short leg that branches off the pipe at an angle, the shape that gives it its name. It is compact, fits in horizontal or vertical lines and suits steam and gas as well as liquids. LEAKPROOF Y-strainers come as cast bodies with flanged ends in standard sizes, and as fabricated bodies with butt-weld or flanged ends, built in Malaysia in carbon or stainless steel for larger sizes, higher pressures and special duties.

1 to 12 in2-1/2 in included; larger fabricated
Cast or fabricatedflanged, butt-weld or threaded ends
Perforated screenmesh-lined for a finer cut
CS, SS304, SS316cast iron and cast stainless on request
Inside the strainer

What Is Inside a LEAKPROOF Y-Strainer

Loading the 3D model…
Drag to turn · double-click a part, + or Ctrl + scroll to zoom · right-drag to move
Turn the model to see every part. The numbers match the list below; also labelled in the model: 11 Collected Debris, 12 Cover Bolts. Model of a 4-inch cast Y-strainer with flanged ends and, with the button, a fabricated Y-strainer with butt-weld ends and a blind-flange cover; proportions follow our drawings.
1

Strainer Body

A cast body with flanged ends, or a fabricated body built from pipe and fittings, with butt-weld or flanged ends.

2

Inlet

The liquid comes in here. The flow arrow on the body shows which end is the inlet.

3

Outlet

The strained liquid leaves on the same centre line, so the strainer fits straight into the pipe run.

4

Partition

A wall across the inside of the body. It leaves the liquid only one way through: into the open end of the screen.

5

Screen Seat

A machined seat in the partition. The open end of the screen lands on it, so nothing can bypass the screen.

6

Screen

A perforated stainless steel cylinder in the leg, plain or lined with mesh. The debris collects inside it.

7

Screen Cover

A bolted cover, or a blind flange on fabricated strainers, closes the leg and holds the screen on its seat.

8

Cover Gasket

EPDM or Viton for most liquids; PTFE or spiral-wound gaskets for hot or high-pressure duties.

9

Drain Plug

A threaded plug in the cover empties the screen. A blow-down valve can be fitted in its place.

10

Flow Arrow

Marked on the body: the strainer must be fitted with the flow, so that the liquid enters the screen.

How it works

Six Steps from Inlet to Clean Screen

A Y-strainer works on the same principle as a basket strainer, laid on its side: the partition sends the liquid into the open end of the screen, and it leaves through the screen wall, from the inside out. The debris is carried down the screen and collects at its closed end, by the cover, where it can be drained or blown down. The diagram and the six steps below follow the liquid through a Y-strainer.

Step 1 of 6: Into the ScreenThe liquid enters through the inlet; the partition leaves it only one way on, into the open end of the screen.
from the line isolation valve isolation valve gauge gauge partition and seat screen cover and drain plug blow-down valve Strained Liquidto the trap, valve or meter In Out
Liquid with debrisStrained liquidDebris held in the screen
1

Into the Screen

The liquid enters through the inlet; the partition leaves it only one way on, into the open end of the screen.

2

Out Through the Screen

It passes through the screen wall from the inside out, into the leg, and on to the outlet.

3

Debris Collects at the End

Particles larger than the holes are carried down the screen and collect at its closed end, by the cover.

4

Watch the Pressure Difference

As the screen fills, the pressure difference across the strainer rises; gauges on each side show when it is due for cleaning.

5

Blow Down

Where a blow-down valve is fitted and the duty allows it, opening it for a moment flushes the debris out of the screen without taking the strainer apart.

6

Clean the Screen

For a thorough clean the line is isolated and drained, the cover taken off and the screen pulled out, washed and put back.

Which way up. In a horizontal liquid line the leg points down, so the debris stays in the screen; in a vertical line the flow must go downwards. On steam and gas lines the leg is often turned to lie on its side, so that condensate does not collect in it.
Why the seat matters. If the screen does not land squarely on its seat, liquid flows around it and the screen protects nothing. That is why the seat of a LEAKPROOF Y-strainer is machined and the cover holds the screen firmly on it.
More debris than a Y can hold? A Y-strainer holds less than a basket strainer. For larger lines or dirtier liquids, a basket strainer is easier to keep clean.
Design and construction

Cast in Standard Sizes, Fabricated in Malaysia to Order

Cast Bodies

Cast iron, cast carbon steel or cast stainless steel (CF8) bodies with flanged ends, in standard sizes from 1 to 12 inches, 2-1/2 inch included.

Fabricated Bodies

Built in our works from pipe and fittings in carbon steel, SS304L or SS316L, for larger sizes, higher ratings and special layouts, designed to ASME B31.1, B31.3 or ASME VIII Div. 1.

Leakproof Seat

The open end of the screen lands on a machined seat in the partition, and the cover holds it there, so nothing flows past the screen.

Screens

Perforated stainless steel, 1/32, 1/16 or 1/8 inch holes, plain or lined with 20 to 60 mesh, or with fine mesh from 60 to 300 µm on fabricated strainers.

Connections

ANSI B16.5 flanges on cast and fabricated bodies; butt-weld ends bevelled for welding into the line; threaded ends on small fabricated strainers.

Pressure Ratings

ANSI 150 lb as standard; fabricated Y-strainers for 300 and 600 lb, and higher ratings designed to order.

Cover and Gasket

A bolted cover or blind flange with an EPDM or Viton gasket; PTFE or spiral-wound gaskets for hot and high-pressure duties.

Drain and Blow-Down

A threaded drain plug in the cover, from 1/4 to 3/4 inch; a blow-down valve, vents and differential pressure connections on request.

Testing and Documents

Hydrostatic test before dispatch; dye penetrant, radiographic, positive material identification, EN 10204 3.1 material certificates, a certificate of conformance and pickling and passivation when the specification asks for them.

Applications

What Y-Strainers Are Used For

A Y-strainer is the usual choice where the line is small, the debris is light, or space is tight. It keeps scale, weld slag and dirt out of the equipment downstream and is cleaned with the line stopped or, where a blow-down valve is fitted, by a short blow-down. These are the usual duties.

Steam Lines

Traps, control valves and heaters

In front of steam traps, control valves and heat exchangers, where scale and weld slag would stop a trap or score a valve seat.

Gas and Fuel Lines

Burners and gas trains

On fuel gas, fuel oil and diesel lines to burners and engines, to keep dirt out of regulators, nozzles and injectors.

Pumps and Meters

Small liquid lines

Ahead of dosing pumps, flow meters and control valves on small lines, where a basket strainer would be too big.

Hot Oil and Process Lines

Plants and refineries

Thermal oil, process liquids and solvents, in carbon or stainless steel, with ratings to suit the line.

High-Pressure Duties

Oil and gas, petrochemical

Fabricated Y-strainers with butt-weld ends for high-pressure lines, built to the project specification and tested.

Water and Utilities

Cooling, process and wash water

Cooling-water, process-water and washdown lines, and compressed air.

Test gauge on a fabricated strainer body
Hydrostatic test before dispatch
20-inch fabricated butt-weld Y-strainer wrapped for delivery
A 20-inch butt-weld Y-strainer, wrapped for delivery
One-inch stainless steel Y-strainers with flanged ends
One-inch stainless steel Y-strainers

Where It Sits in a Line

Pipe line
liquid, steam or gas with some dirt
Isolation valve
closed to clean the screen
Y-strainer
catches scale and slag
Blow-down valve
flushes the screen, where fitted
Control valve or trap
protected from debris
Process
clean flow downstream

A gauge on each side shows when the screen is due. On steam lines a blow-down valve on the cover is a quick way to keep the screen clear between shutdowns.

When a Y-Strainer Is the Right Choice

  • Small and medium lines, light debris, and steam, gas or liquid service.
  • Tight spaces and vertical lines with downward flow.
  • High pressures, with a fabricated body and butt-weld ends.
  • Lines where a blow-down valve can keep the screen clear between shutdowns.

When Another Strainer Is Better

  • Larger lines or a fair amount of debris: a simplex basket strainer holds far more.
  • A line that must not stop: a duplex basket strainer.
  • Debris that comes only once, at commissioning: a temporary cone, basket or plate strainer.

For more debris see the LEAKPROOF simplex basket strainer; for a line that must keep running, the LEAKPROOF duplex basket strainer; for commissioning, temporary cone, basket and plate strainers.

LEAKPROOF Y-strainers, cast and fabricated, protect steam, gas, fuel and process lines in refineries, chemical and oleochemical plants, power and utility plants and shipyards in Malaysia, Singapore and Indonesia, from one-inch flanged strainers to large butt-weld strainers built and tested to a project specification.
Models and dimensions

Cast and Fabricated Y-Strainers

Cast Y-strainers cover the common sizes with flanged ends; fabricated Y-strainers are built to order for larger lines, higher ratings, butt-weld ends and special materials. We size each strainer for the line, the flow and the debris.

Small cast Y-strainers with flanged ends and bolted covers

Cast Y-Strainer, LP150Y2

Cast body with flanged ends in standard sizes from 1 to 12 inches, 2-1/2 inch included: the first table below.

Fabricated high-pressure Y-strainers with butt-weld ends and bolted covers

Fabricated Butt-Weld, LP150Y5

Built from pipe in carbon or stainless steel and welded into the line: the second table.

Large fabricated flanged Y-strainer, painted, with a blow-down connection

Fabricated Flanged and Special

Flanged bodies, larger legs, blow-down valves and higher ratings, built to the project drawing.

Cast Y-Strainers, Flanged, LP150Y2

Size (in)L (mm)D (mm)C (mm)B (mm)H1 (mm)Drain (BSPT)Weight (kg)
1160108792577none3.4
2220152120501281/2 in9.0
3290190152802001/2 in18.5
43502291901002401/2 in27.0
64402792411503001/2 in50.0
85403432982004101/2 in100.0
106404063622504751/2 in147.0
128054844323006001/2 in216.0

L: face to face. D: flange diameter. C: bolt circle. B: bore. H1: centre line to the bottom of the cover. Weights are estimates. 2-1/2 inch Y-strainers are also supplied; dimensions on request.

Fabricated Y-Strainers, Butt-Weld, LP150Y5

Size (in)NPS (mm)L (mm)L1 (mm)H (mm)Drain (BSPT)Weight (kg)
2502901102101/4 in9.5
3803801402601/2 in20.8
41004201503001/2 in31.8
61505201804001/2 in61.5
82006102105003/4 in108.0
102507402506003/4 in177.0
123008202807003/4 in246.0

L: end to end. L1: inlet end to the centre of the leg. H: centre line of the pipe to the cover, along the leg. Weights are estimates.

Standard Specification

Body, castCast iron, cast carbon steel or cast stainless steel CF8
Body, fabricatedCarbon steel, SS304L or SS316L (other alloys on request)
EndsANSI B16.5 flanged; butt-weld or threaded on fabricated strainers
Pressure ratingANSI 150 lb standard; 300 and 600 lb fabricated, higher to order
ScreenPerforated stainless steel, 1/32, 1/16 or 1/8 inch holes
Mesh lining20 to 60 mesh; 60 to 300 µm on fabricated strainers
GasketEPDM or Viton; PTFE or spiral wound on request
DrainThreaded BSPT plug in the cover; blow-down valve on request
TestsHydrostatic; DP, RT and PMI on request

Dimensions are for the standard strainers and may change; the general arrangement drawing sent with each quotation gives the certified dimensions and weights.

Spares

Screens and Spares

Screens are the part a Y-strainer uses up. We make perforated and mesh-lined screens in our own works, for our strainers and for other makes, to a drawing, a sample or the main dimensions.

Tall perforated stainless steel screen for a strainer

Replacement Screens

Perforated stainless steel screens made to the length and diameter of your strainer.

Batch of cylindrical woven mesh basket elements wrapped for dispatch

Mesh Screens and Linings

Woven mesh screens and linings for a finer cut, made to size.

Two strainer baskets re-meshed with new woven mesh

Re-meshing

Worn or torn screens and baskets re-meshed with new woven mesh on the old frame.

FAQ

Frequently Asked Questions

What does a Y-strainer do?

It keeps scale, weld slag and dirt out of pumps, control valves, meters, steam traps and burners. The liquid passes from the inside of a cylindrical screen to the outside, and the debris collects in the screen until it is drained or the screen is cleaned.

Y-strainer or basket strainer: which do I need?

A Y-strainer is compact, fits horizontal and vertical lines and suits steam and gas; a basket strainer holds far more debris and is easier to clean, so it suits larger liquid lines and dirtier service. Tell us the line, the medium and the debris, and we will recommend one.

How should a Y-strainer be installed?

With the flow arrow pointing downstream. In a horizontal liquid line the leg points down; in a vertical line the flow must go downwards; on steam and gas lines the leg is often turned to lie on its side. Leave room to take the cover off and pull the screen out.

What is a blow-down valve for?

A valve in place of the drain plug lets the debris be flushed out of the screen by opening it for a moment, without taking the strainer apart. Use it only where the duty allows the release of the line contents, and route the discharge safely.

How do I choose the screen?

By what the equipment downstream must be protected from. Perforated screens protect most pumps and valves; a mesh lining gives a finer cut for meters, nozzles and traps. A finer screen than needed only blocks sooner.

What is the difference between cast and fabricated Y-strainers?

Cast Y-strainers come in standard sizes with flanged ends. Fabricated Y-strainers are built from pipe and fittings, so they can be larger, take higher ratings and butt-weld ends, and be made in the material and layout of the project.

Which pressure ratings are available?

ANSI 150 lb as standard. Fabricated Y-strainers are built for 300 and 600 lb, and higher ratings are designed to order; every strainer is pressure tested before dispatch.

Do you supply screens for other makes?

Yes. Send the length, diameter, perforation or mesh and material, or a sample, and we will make new screens or re-mesh the old ones.

Need a Quote or a Sizing Check?

Send us your duty, a drawing or a photo of your existing unit. A Peltech engineer will reply with options and a quotation.